TE40 Series

40W Level VI Compliant External Power Supplies

A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE40 series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22. Designed to allow easy integration with test and measurement equipment and other industrial applications.

Features

  • AC Input, 90-264Vac, single phase.
  • Input Current, 1.2A at 110Vac, 0.6A at 240Vac
  • Inrush Current, 40A, 264Vac, cold start at 25C
  • Input Fuses, 2.0A, 250Vac
  • Earth Leakage Current, <500A@264Vac, 60Hz input, NC
  • Turn On Time, <700mS at 115Vac.
  • Holdup Time, >20mS
  • Efficiency, Meets Efficiency Level VI Requirements
  • Overload Protection, 130% - 180% of rated output current value. Hiccup Mode, Auto-recovery
  • Short Circuit Protection, Hiccup Mode , Auto-recovery
  • Total Regulation, 5.0 % for all models.
  • Isolation, Input-Output: 4000Vac, Input-Ground: 1500Vac, Output-Ground: 1500Vac
  • Operating Temperature, -20 to +50C, -40C Startup
  • E-Cap Life:, >8 years, calculated at 115/230Vac input, 25C ambient, 24 hrs/day, 365 days/yr.
  • MTBF, >1,000,000 hours per Telcordia
  • Weight, 250g, typical

Detailed Specifications

AC Input
90-264Vac, single phase.
Input Current
1.2A at 110Vac, 0.6A at 240Vac
Inrush Current
40A, 264Vac, cold start at 25C
Input Fuses
2.0A, 250Vac
Earth Leakage Current
<500A@264Vac, 60Hz input, NC
Turn On Time
<700mS at 115Vac.
Holdup Time
>20mS
Efficiency
Meets Efficiency Level VI Requirements
Overload Protection
130% - 180% of rated output current value. Hiccup Mode, Auto-recovery
Short Circuit Protection
Hiccup Mode , Auto-recovery
Total Regulation
5.0 % for all models.
Isolation
Input-Output: 4000Vac, Input-Ground: 1500Vac, Output-Ground: 1500Vac
Operating Temperature
-20 to +50C, -40C Startup
E-Cap Life:
>8 years, calculated at 115/230Vac input, 25C ambient, 24 hrs/day, 365 days/yr.
MTBF
>1,000,000 hours per Telcordia
Weight
250g, typical